Honeywell Series 3000, toxic and oxygen gas detection sensors
The Series 3000 from Honeywell
Analytics provide comprehensive monitoring of toxic and oxygen gas hazards in potentially explosive atmospheres. Suitable for mounting
both indoors and out, they are available in two versions and offer excellent versatility.
The MkII is contained in a flameproof housing, has an intrinsically safe sensor connection and is for use in predominantly Zone 1 applications. However with the use of the optional remote mounting kit the sensor of the MkII can be mounted in a Zone 0 environment. The MkIII is for use with a separate suitable IS barrier allowing the complete transmitter to be used in Zone 0 applications.
These low powered gas detectors all feature a loop powered 4-20 mA connection, making them ideal for both new and retrofit installations. Users can configure the detector through the use of the easy to read LCD and intuitive interface while fault diagnostic software and a programmable calibration period greatly simplify maintenance procedures.
The intrinsically safe smart sensors are supplied pre-configured and can be ‘hot swapped’ without having to remove power to the detector, saving time and money during commissioning and routine servicing. A remote sensor mounting kit is available that allows the sensor to be mounted up to 15m (50ft) from the transmitter, making it ideal for operation in areas that are difficult to access.
Series 3000 is supplied with all necessary accessories for easy installation. The detector can be wall mounted using the integral mounting lugs or pipe mounted (horizontal or vertical) using the optional pipe mounting kit. Electrical installation is made using the 2 x M20 cable entries (ATEX/IECEx version) or 2 x ¾”NPT conduit entries (UL/c-UL versions). A suitable blanking plug is also supplied to seal any unused entries. A weatherproof cap is also included for use in the harshest outdoor conditions.
Series 3000 is ideal to integrate with existing industry standard 4-20mA loop systems or with a choice of controllers such as the Honeywell Zareba Unipoint.
The MkII is contained in a flameproof housing, has an intrinsically safe sensor connection and is for use in predominantly Zone 1 applications. However with the use of the optional remote mounting kit the sensor of the MkII can be mounted in a Zone 0 environment. The MkIII is for use with a separate suitable IS barrier allowing the complete transmitter to be used in Zone 0 applications.
These low powered gas detectors all feature a loop powered 4-20 mA connection, making them ideal for both new and retrofit installations. Users can configure the detector through the use of the easy to read LCD and intuitive interface while fault diagnostic software and a programmable calibration period greatly simplify maintenance procedures.
The intrinsically safe smart sensors are supplied pre-configured and can be ‘hot swapped’ without having to remove power to the detector, saving time and money during commissioning and routine servicing. A remote sensor mounting kit is available that allows the sensor to be mounted up to 15m (50ft) from the transmitter, making it ideal for operation in areas that are difficult to access.
Series 3000 is supplied with all necessary accessories for easy installation. The detector can be wall mounted using the integral mounting lugs or pipe mounted (horizontal or vertical) using the optional pipe mounting kit. Electrical installation is made using the 2 x M20 cable entries (ATEX/IECEx version) or 2 x ¾”NPT conduit entries (UL/c-UL versions). A suitable blanking plug is also supplied to seal any unused entries. A weatherproof cap is also included for use in the harshest outdoor conditions.
Series 3000 is ideal to integrate with existing industry standard 4-20mA loop systems or with a choice of controllers such as the Honeywell Zareba Unipoint.
- Features:
- Proven electrochemical sensing technology
- Uses Surecell" electrochemical cells, ideal for hot and humid environments
- Long-life sensing elements (typical >2 years)
- Surecell and Reflex - Superior performance sensing technology. Increased accuracy and reliability. Determines the health of O2 and toxic cells. Detects “dry-out” of the sensor cell. Ensures highest level of “up-time”
- Plug and play factory configured sensors
- Non-intrusive operation - Easy routine maintenance. No need to open the transmitter. Faster planned maintenance. Greater operator confidence
- Housing material options - aluminium alloy or Stainless Steel 316
- Easy to install - Simple plug-in sensors. Integral wall mount lugs. Separate kit for vertical/horizontal pipe mount.
- Series 3000 supplied complete with:
- Series 3000 transmitter with integral surface mounting lugs
- 2 x M20 cable entries (ATEX/IECEx certified versions)
- 2 x ¾ cable entries (UL/c-UL versions)
- 1 x blanking plug
- Magnetic wand and Allen key
- User manual
- Optional accessories:
- 3220-012 S3KCAL Calibration cap
- 3220-013 S3KCC Collecting cone (for use with detecting hydrogen gas only)
- 3220-009 S3KDMK Duct mounting kit (O2, CO, H2S or H2 gas only)
- 3220-010 SPXCDMTBR Pipe Mounting bracket (inc. fixings and hex wrench set)
- 3220-011 SPXCDSDP Sunshade/Deluge Protection
- 3220-014 S3KRMK ATEX/UL/c-UL approved remote sensor mounting kit (includes enclosure with sensor socket, 15m (50 feet) of digital cable and glands, transmitter cable plug, mounting screws)
- Replacement gas sensors available. Contact the sales office quoting part number:
- 3570-201 Oxygen 0-25%VOL (S3KO1SS)
- 3570-202 Carbon Monoxide 0-300ppm (100 to 999ppm, 100ppm) (S3KC1SS)
- 3570-204 Hydrogen Sulphide 0-15ppm (10 to 50ppm, 1ppm) (S3KH1SS)
- 3570-205 Hydrogen Sulphide 0-100ppm (50 to 500ppm, 10ppm) (S3KH2SS)
- 3570-206 Chlorine 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm) (S3KL1SS)
- 3570-207 Sulphur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm) (S3KS1SS)
- 3570-208 Chlorine Dioxide 0-1.00ppm (S3KX1SS)
- 3570-209 Nitrogen Monoxide 0-100ppm 9S3KM1SS)
- 3570-210 Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm) (S3KN1SS)
- 3570-211 Hydrogen 0-1000ppm (S3KG1SS)
- 3570-212 Hydrogen 0-10,000ppm (S3KG2SS)
- 3570-213 Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm) (S3KR1SS)
- 3570-214 Ammonia 0-200ppm (50 to 200ppm, 50ppm) (S3KA1SS)
- 3570-215 Ammonia 0-1000ppm (200 to 1000ppm, 50ppm) (S3KA2SS)
- 3570-216 Hydrogen Cyanide 0-30.0ppm (S3KY1SS)
- 3570-217 Hydrogen Flouride 0-12.0pm (S3KF1SS)
- 3570-218 Phospine 0-1.2ppm (S3KP1SS)
Series 3000 MkII datasheet |
Series 3000 MkII user manual |
Buy the Series 3000 MkII now, Tel: 01279 307100
3570-001 | Honeywell Series 3000 MkII ATEX/IECEX approved transmitter (S3KAL2) alum. alloy | POA | |
3570-002 | Honeywell Series 3000 MkII ATEX/IECEX approved transmitter (S3KAS2) stainless steel | POA | |
3570-003 | Honeywell Series 3000 MkII UL/c-UL approved transmitter (S3KUL2) alum. alloy | POA | |
3570-004 | Honeywell Series 3000 MkII UL/c-UL approved transmitter (S3KUS2) stainless steel | POA | |
3570-005 | Honeywell Series 3000 MkIII ATEX/IECEX approved transmitter (S3KAL3) alum. alloy | POA | |
3570-006 | Honeywell Series 3000 MkIII ATEX/IECEX approved transmitter (S3KAS3) stainless steel | POA | |
3570-007 | Honeywell Series 3000 MkIII UL/c-UL approved transmitter (S3KUL3) alum. alloy | POA | |
3570-008 | Honeywell Series 3000 MkIII UL/c-UL approved transmitter (S3KUS3) stainless steel | POA | |
3570-101 | Honeywell Series 3000 Smart Sensor 0-25%VOL Oxygen (S3KXSO1SS) | POA | |
3570-102 | Honeywell Series 3000 Smart Sensor 0-100, 0-300 (default), 0-500ppm Carbon monoxide (S3KXSC1SS) | POA | |
3570-103 | Honeywell Series 3000 Smart Sensor 0-100, 0-300 (default), 0-999ppm Carbon monoxide (S3KXSC2SS) | POA | |
3570-104 | Honeywell Series 3000 Smart Sensor 0-10, 0-15 (default), 0-50ppm Hydrogen sulphide (S3KXSH1SS) | POA | |
3570-105 | Honeywell Series 3000 Smart Sensor 0-50, 0-100 (default), 0-500ppm Hydrogen sulphide (S3KXSH2SS) | POA | |
3570-106 | Honeywell Series 3000 Smart Sensor 0-5.0 (default), 0-20ppm Chlorine (S3KXSL1SS) | POA | |
3570-107 | Honeywell Series 3000 Smart Sensor 0,5.0, 0-15.0 (default), 0-20.0ppm Sulphur dioxide (S3KXSS1SS) | POA | |
3570-108 | Honeywell Series 3000 Smart Sensor 0-1.00ppm Chlorine dioxide (S3KXSX1SS) | POA | |
3570-109 | Honeywell Series 3000 Smart Sensor 0-100ppm Nitrogen monoxide (S3KXSM1SS) | POA | |
3570-110 | Honeywell Series 3000 Smart Sensor 0-5, 10 (default), 0-50ppm Nitrogen dioxide (S3KXSN1SS) | POA | |
3570-111 | Honeywell Series 3000 Smart Sensor 0-1000ppm Hydrogen (S3KXSG1SS) | POA | |
3570-112 | Honeywell Series 3000 Smart Sensor 0-10,000ppm Hydrogen (S3KXSG2SS) | POA | |
3570-113 | Honeywell Series 3000 MkII Smart Sensor 0-10 (default), 0-20ppm Hydrogen chloride (S3KXSR1SS) | POA | |
3570-114 | Honeywell Series 3000 Smart Sensor 0-50, 0-200ppm (default) Ammonia (S3KXSA1SS) | POA | |
3570-115 | Honeywell Series 3000 Smart Sensor 0-200, 0-1000ppm (default) Ammonia (S3KXSA2SS) | POA | |
3570-116 | Honeywell Series 3000 Smart Sensor 0-30.0ppm (default) Hydrogen cyanide (S3KXSY1SS) | POA | |
3570-117 | Honeywell Series 3000 Smart Sensor 0-12.0ppm (default) Hydrogen flouride (S3KXSF1SS) | POA | |
3570-118 | Honeywell Series 3000 Smart Sensor 0-1.2ppm (default) Phosphine(S3KXSP1SS) | POA |
Fill out my online form.