Honeywell Sensepoint XCD transmitters and gas detection sensors

The Sensepoint XCD (Exceed) range of fixed gas detectors is used to monitor areas where flammable, oxygen deficiency and toxic gases may pose a hazard to working environments. Incorporating all the advantages of leading edge, fixed industrial gas detection technology, XCD offers high performance and reliability synonymous with the Honeywell Analytics brand. XCD is designed for a broad spectrum of industrial applications with a comprehensive choice of features and benefits in a truly cost effective package.

This advanced and versatile range of gas detectors monitors and indicates the presence of any one of many toxic and flammable gases. Any user can instantly identify the operating status of XCD via its clear multi-function backlit display. Output signals available are industrial standard 4 to 20mA, relay contacts and MODBUS. Routine maintenance, diagnostics and options to customize XCD factory defaults can be achieved without opening the unit.

Sensepoint XCD uses a number of patented sensing technologies in its core design which reflect over 40 years of global experience associated with the famous Sieger name. These include poison resistant catalytic bead for flammable gases and electrochemical cell for toxic gases. Non-dispersed Infrared (NDIR) technology is available to those users who require more robust detection with longer sensor operating lifetime. As a result, XCD is suitable for many light and heavy industries. In addition, the design of XCD reflects outstanding performance, whether it is used in harsh outdoor environments or sheltered indoor applications.

Sensepoint XCD from Honeywell Analytics (manufacturers of toxic and flammable gas detection systems under the Sieger and Zareba brands) can be used 'stand alone' or with a choice of controllers such as the Honeywell Zareba Unipoint, or operated from a customer´s own existing system due to the use of industry standard outputs.

Note: Sensepoint XCD flammable is preconfigured for 0-100% LEL methane. Contact the sales office for other flammable gas configurations.
  • Features:
    • Common transmitter platform - Same transmitter structure applicable to a variety of new and existing gas sensors. Local/remote sensor capability. Uses ECC/Catalytic/IR sensing technology. Smart intelligence recognises sensor type & range
    • Clear and informative display - Tri-colour backlight on LCD display. Instantly and clearly visible from a distance. Helps to clarify operation status in adverse situations
    • Multiple signal outputs - 4 to 20mA standard. Switching relays. Modbus
    • Surecell and Reflex - Superior performance sensing technology. Increased accuracy and reliability. Determines the health of O2 and toxic cells. Detects “dry-out” of the sensor cell. Ensures highest level of “up-time”
    • Infrared sensing technology - Low cost IR solution. Longer service life. No poisons. Doesn’t need oxygen
    • Non-intrusive operation - Easy routine maintenance. No need to open the transmitter. Faster planned maintenance. Greater operator confidence
    • Housing material options - aluminium alloy or Stainless Steel 316
    • Easy to install - Simple plug-in sensors. Integral plate for wall mount. Separate kit for vertical/horizontal pipe mount. On board relays allow for local alarms. 3 wire operation, source or sink
    • Universal junction box
    • Includes earth continuity plate for added RFI protection
Sensepoint XCD consists of transmitter and sensor. Some special sensor applications should be ordered separately, but standard sensors such as CAT/IR/EC sensor should be ordered with only one KIT part number (see below).
  • Sensepoint XCD supplied complete with:
    • XCD transmitter
    • Sensor cartridge
    • Standard weather protection
    • Magnetic wand and Allen key
    • User manual
  • Optional accessories:
    • S3KCAL Calibration cap
    • SPXCDCC Collecting cone for use with lighter than air gases
    • SPXCDDMK Duct mounting kit
    • SPXCDMTBR Pipe Mounting bracket (inc. fixings and hex wrench set)
    • SPXCDSDP Sunshade/Deluge Protection
  • Replacement gas sensors available. Contact the sales office quoting part number:
    • 3532-201 0-100% LEL flammable catalytic (SPXCDXSFXSS)
    • 3532-202 0-100% LEL flammable infra-red (SPXCDXSRXSS)
    • 3532-203 0-100% LEL propane infra-red (SPXCDXSPXSS)
    • 3532-204 0-25% volume oxygen (SPXCDXSO1SS)
    • 3532-205 0-10ppm nitrogen dioxide (SPXCDXSNXSS)
    • 3532-206 0-50ppm hydrogen sulphide (SPXCDXSHXSS)
    • 3532-207 0-300ppm carbon monoxide (SPXCDXSCXSS)
    • 3532-208 0-1000ppm hydrogen (SPSTAXG1SS)
    • 3532-209 0-2.00% volume carbon dioxide infra-red (SPXCDXSB1SS)
Honeywell Sensepoint XCD gas detection sensors datasheet Sensepoint XCD
datasheet
Honeywell Sensepoint XCD gas detection sensor user manual Sensepoint XCD
user manual
Buy the Sensepoint XCD now, Tel: 01279 307100
3532-001 Sensepoint XCD 0-100% LEL flammable catalytic gas sensor (SPXCDALMFX) alum. alloy POA
3532-002 Sensepoint XCD 0-100% LEL flammable (methane) infra-red gas sensor (SPXCDALMRX) alum. alloy POA
3532-003 Sensepoint XCD 0-100% LEL flammable (propane) infra-red gas sensor (SPXCDALMPX) alum. alloy POA
3532-004 Sensepoint XCD 0-25% volume oxygen gas sensor (SPXCDALMO1) alum. alloy POA
3532-005 Sensepoint XCD 0-10ppm nitrogen dioxide gas sensor (SPXCDALMNX) alum. alloy POA
3532-006 Sensepoint XCD 0-50ppm hydrogen sulphide gas sensor (SPXCDALMHX) alum. alloy POA
3532-007 Sensepoint XCD 0-300ppm carbon monoxide gas sensor (SPXCDALMCX) alum. alloy POA
3532-008 Sensepoint XCD 0-1000ppm hydrogen gas sensor (SPXCDALMG1) alum. alloy POA
3532-009 Sensepoint XCD 0-2.00% volume carbon dioxide infra-red gas sensor (SPXCDALMB1) alum. alloy POA
3532-101 Sensepoint XCD 0-100% LEL flammable catalytic gas sensor (SPXCDASMFX) 316 SS POA
3532-102 Sensepoint XCD 0-100% LEL flammable (methane) infra-red gas sensor (SPXCDASMRX) 316 SS POA
3532-103 Sensepoint XCD 0-100% LEL flammable (propane) infra-red gas sensor (SPXCDASMPX) 316 SS POA
3532-104 Sensepoint XCD 0-25% volume oxygen gas sensor (SPXCDASMO1) 316 SS POA
3532-105 Sensepoint XCD 0-10ppm nitrogen dioxide gas sensor (SPXCDASMNX) 316 SS POA
3532-106 Sensepoint XCD 0-50ppm hydrogen sulphide gas sensor (SPXCDASMHX) 316 SS POA
3532-107 Sensepoint XCD 0-300ppm carbon monoxide gas sensor (SPXCDASMCX) 316 SS POA
3532-108 Sensepoint XCD 0-1000ppm hydrogen gas sensor (SPXCDASMG1) 316 SS POA
3532-109 Sensepoint XCD 0-2.00% volume carbon dioxide infra-red gas sensor (SPXCDASMB1) 316 SS POA
3532-301 Sensepoint XCD with Modbus 0-100% LEL flammable catalytic gas sensor (SPXCDALMFXM) alum. alloy POA
3532-302 Sensepoint XCD with Modbus 0-100% LEL flammable (methane) infra-red gas sensor (SPXCDALMRXM) alum. alloy POA
3532-303 Sensepoint XCD with Modbus 0-100% LEL flammable (propane) infra-red gas sensor (SPXCDALMPXM) alum. alloy POA
3532-304 Sensepoint XCD with Modbus 0-25% volume oxygen gas sensor (SPXCDALMO1M) alum. alloy POA
3532-305 Sensepoint XCD with Modbus 0-10ppm nitrogen dioxide gas sensor (SPXCDALMNXM) alum. alloy POA
3532-306 Sensepoint XCD with Modbus 0-50ppm hydrogen sulphide gas sensor (SPXCDALMHXM) alum. alloy POA
3532-307 Sensepoint XCD with Modbus 0-300ppm carbon monoxide gas sensor (SPXCDALMCXM) alum. alloy POA
3532-308 Sensepoint XCD with Modbus 0-1000ppm hydrogen gas sensor (SPXCDALMG1M) alum. alloy POA
3532-309 Sensepoint XCD with Modbus 0-2.00% volume carbon dioxide infra-red gas sensor (SPXCDALMB1M) alum. alloy POA
3532-401 Sensepoint XCD with Modbus 0-100% LEL flammable catalytic gas sensor (SPXCDASMFXM) 316 SS POA
3532-402 Sensepoint XCD with Modbus 0-100% LEL flammable (methane) infra-red gas sensor (SPXCDASMRXM) 316 SS POA
3532-403 Sensepoint XCD with Modbus 0-100% LEL flammable (propane) infra-red gas sensor (SPXCDASMPXM) 316 SS POA
3532-404 Sensepoint XCD with Modbus 0-25% volume oxygen gas sensor (SPXCDASMO1M) 316 SS POA
3532-405 Sensepoint XCD with Modbus 0-10ppm nitrogen dioxide gas sensor (SPXCDASMNXM) alum. alloy POA
3532-406 Sensepoint XCD with Modbus 0-50ppm hydrogen sulphide gas sensor (SPXCDASMHXM) 316 SS POA
3532-407 Sensepoint XCD with Modbus 0-300ppm carbon monoxide gas sensor (SPXCDASMCXM) 316 SS POA
3532-408 Sensepoint XCD with Modbus 0-1000ppm hydrogen gas sensor (SPXCDASMG1M) 316 SS POA
3532-409 Sensepoint XCD with Modbus 0-2.00% volume carbon dioxide infra-red gas sensor (SPXCDASMB1M) 316 SS POA
Fill out my online form.